International Free Phone - (00) 800 9027 0899
United States Toll Free Phone - 800 296 1579
Comments
What do you think of our website?

Low Light Imaging Cameras

iXonEM+ 885 EMCCD Camera

885

A proud member of Andor’s iXonEM+ EMCCD range, the 885 benefits from the unique innovations and high-end performance specifications that have characterized this camera family as the industry’s leading high-performance EMCCD.

The megapixel sensor format and 8 x 8μm pixel size of the 885 presents an attractive combination of field of view and resolution, offering excellent Nyquist over-sampling for cell microscopy.

When more light is available from the sample, the EMCCD gain can be completely switched off and the camera operated as a 'traditional' CCD camera. However if the camera is used in low-light conditions, the EMCCD gain can be applied to render it single photon sensitive, while maintaining a full resolution frame rate of 31 frames/sec. The absolute EM gain multiplication can be varied linearly from unity up to a thousand times directly via RealGainTM, a true quantitative EM gain scale.

Technical Specifications

  • What does this specification mean?Active Pixels

    1004 x 1002

  • Pixel Size (µm)

    8

  • Image Area

    8mm x 8mm

  • What does this specification mean? Act. Area Pixel Well Depth (e-, typical)

    40000

  • Gain Reg. Pix. Well Depth (e-, typical)

    80000

  • Max Readout Rate

    35MHz

  • What does this specification mean? Frame Rate (fps)

    31.4

  • Read Noise (e-, typical)

    25 @ 35MHz
    < 1 with EM Gain

Features and Benefits

  • EMCCD Technology

    Even single photon signals are amplified above the noise floor. Full QE of CCD chip is harnessed (no intensifier).

  • RealGain™

    Absolute EMCCD gain selectable directly from a linear and quantitative scale.

  • iCam

    Unique innovation that empowers the EMCCD to operate with market-leading acquisition efficiency through live cell microscopy software.

  • TE Cooling to -95°C

    Critical for elimination of darkcurrent detection limit.

  • > 65% QE from Virtual Phase Sensor

    Highly efficient photon collection. One window design.

  • Variable Readout Rates Up To 35 MHz

    Quantitative accuracy at all speeds.

  • 8 x 8μm Pixel Size (Fully Binnable)

    Excellent balance of NyQuist resolution and photon collection.

  • UltraVac™

    Critical for sustained vacuum integrity and to maintain unequalled cooling and QE performance, year after year.

  • Minimal Clock-Induced Charge

    Giving lowest “spurious noise” specification; essential for single photon counting.

  • Enhanced Baseline Clamp

    Essential for quantitative accuracy of dynamic measurements.

  • Negligible EM Gain Ageing

    No requirement for gain recalibration.

  • Built-in C-mount Compatible Shutter (Optional)

    Easy means to record control dark images - excellent for optimization of experimental set-up.

  • Cropped Sensor Mode

    Specialized readout mode for achieving sub-millisecond temporal resolution from EMCCD and CCD cameras. Intuitive Cropped Sensor definition for continuous rapid image or spectral acquisition.

Quantum Efficiency Curve

QE Data17

Build System

Controller Cards

You will require one of these options to operate this camera

Software

You will require one of these options to operate this camera

  • 3rd Party Software CompatibilityDrivers are available so the camera can operate through popular third party imaging software packages. Please contact us for a list of to see if you software is compatible Add to wishlist

  • iQThe best live cell imaging software just got betterAdd to wishlist

  • SDKAndor Software Development Kit (SDK)Add to wishlist

  • Solis (I)Solis-I for Imaging CamerasAdd to wishlist

Cooling Options

  • XW-CHIL-150Ultra compact chiller unit for ultimate cooling performanceAdd to wishlist

  • XW-RECRRe-circulator for enhanced cooling performanceAdd to wishlist