Andor’s iXonEM Blue back-illuminated EMCCD has single photon detection capability combined with exceptional QE performance in the blue wavelength region. Part of the acclaimed iXonEM+ platform, Blue is designed to extract the absolute best from quantitative EMCCD technology across all critical performance parameters, in addition offering greater than 20% extra QE response to blue photons (compared to the ‘standard’ back-illuminated QE curve).
512 x 512
The smallest elements of a CCD detector grid.
16
8.2mm x 8.2mm
160000 Maximum: 220000
The well depth of a single pixel on the ccd sensor
800000
10MHz
35
Frame rate, or frame frequency, is the measurement of how quickly an imaging device produces unique consecutive images called frames
< 1 to 49 @ 10 MHz
Compared to the ‘standard’ back-illuminated QE curve, iXonEM Blue offers enhanced QE between 300nm to 470nm (70% @ 380nm).
Even single photon signals are amplified above the noise floor. Full QE of CCD chip is harnessed (no intensifier).
Critical for elimination of darkcurrent detection limit.
Absolute EMCCD gain selectable directly from a linear and quantitative scale.
Innovative user-initiated self-recalibration of EM Gain.
Unique innovation that empowers the Clara to operate with market-leading acquisition efficiency through live cell microscopy software
Critical for sustained vacuum integrity and to maintain unequalled cooling and QE performance, year after year.
Quantitative accuracy at all speeds. Slower readout rate for enhanced 16-bit dynamic range.
Highly flexible camera optimized for both fast, ultra lowlight imaging and ‘bright-field’ or conventional fluorescence imaging.
Extended sensor dynamic range (readout speed dependent) and matched digitization for quantization of dim and bright signals.
Giving lowest “spurious noise” specification; essential for single photon counting.
Specialized readout mode for achieving sub-millisecond temporal resolution from EMCCD and CCD cameras. Intuitive Cropped Sensor definition for continuous rapid image or spectral acquisition.
Essential for quantitative accuracy of dynamic measurements.
Easy means to record control dark images - excellent for optimization of experimental set-up.
You will require one of these options to operate this camera
CCI-23PCI controller cardAdd to wishlist
3rd Party Software CompatibilityDrivers are available so the camera can operate through popular third party imaging software packages. Please contact us for a list of to see if you software is compatible Add to wishlist
iQThe best live cell imaging software just got betterAdd to wishlist
SDKAndor Software Development Kit (SDK)Add to wishlist
Solis (I)Solis-I for Imaging CamerasAdd to wishlist
XW-CHIL-150Ultra compact chiller unit for ultimate cooling performanceAdd to wishlist
XW-RECRRe-circulator for enhanced cooling performanceAdd to wishlist